PAIN AND EFFICIENCY IN NEONATAL BLOOD SAMPLE SCREENINGS - New Devices for Reducing Pain and Improving Blood Sample Quality
Bruno Wacogne, Christian Pieralli, Gonzalo Cabodevila, Nolwenn Baron, Sandrine Marioli, Lionel Pazart
2009
Abstract
Neonatal blood sample screening is recognised as a difficult gesture and painful to the newborns. The number of detected diseases is still relatively low and depends on the country where it is performed. There is a real need for new techniques that reduce pain, facilitate the blood sampling, increase the quantity of sampled blood and improve the collection of blood of the cardboard blotter actually used. In this paper, we present systems that are currently developed in Besançon (France) in collaboration between the FEMTO-ST Institute and the University Hospital. They mainly concern micro-needles arrays and pressure free blood sampling devices. The choice of these systems has been dictated by a study of the pain that newborns feel during the gesture. The ulterior motive of this work is to improve neonatal blood sample screenings and therefore, to increase the number of screened diseases and try to generalise this technique to places where it is not yet done.
References
- Destruynder, R., Lassauge, F., Menget, et al., 1991, Pain in the newborn in an intensive care unit, Pediatrie, Vol. 46, pp. 535-539.
- Facchini, A., Bellieni, CV., 2005, Relating pain intensity of newborns to onset of nonlinear phenomena in cry recordings, Physics Letters A, Vol. 338, pp. 332-337.
- Mukerjee, E., Collins, S., Isserof, et al., 2004, Microneedles array for transdermal biological fluid extraction and in situ analysis, Sensors and Actuators A, Vol. 114, pp. 267-275.
- Oka, K., Aoyagi, S., Isono, et al., 2001, Fabrication of a micro-needle for a trace blood test, Transducer'01 Digest of Technical Papers, pp. 412-415.
- Owens, ME., Todt, EH., Pain in infancy : neonatal reaction to a heel lance, 1984, Pain, Vol. 20, pp. 77- 86.
- Sharaf, R., Aggarwal, P., Kaler, K., et al., 2003, On the design of an electronic mosquito : design and analysis of the micro-needle, Proceedings of the International Conference on MEMS, NANO and Smart Systems, pp. 32-35.
- Uyan, ZS., Bilgen, H., Topuzoglu, et al., Comparison of three neonatal pain scales during minor painful procedures, 2008, Journal of Maternal-Fetal and Neonatal Medicine, Vol. 21, pp. 305-308.
Paper Citation
in Harvard Style
Wacogne B., Pieralli C., Cabodevila G., Baron N., Marioli S. and Pazart L. (2009). PAIN AND EFFICIENCY IN NEONATAL BLOOD SAMPLE SCREENINGS - New Devices for Reducing Pain and Improving Blood Sample Quality . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009) ISBN 978-989-8111- 64-7, pages 290-295. DOI: 10.5220/0001776902900295
in Bibtex Style
@conference{biodevices09,
author={Bruno Wacogne and Christian Pieralli and Gonzalo Cabodevila and Nolwenn Baron and Sandrine Marioli and Lionel Pazart},
title={PAIN AND EFFICIENCY IN NEONATAL BLOOD SAMPLE SCREENINGS - New Devices for Reducing Pain and Improving Blood Sample Quality},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)},
year={2009},
pages={290-295},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001776902900295},
isbn={978-989-8111- 64-7},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)
TI - PAIN AND EFFICIENCY IN NEONATAL BLOOD SAMPLE SCREENINGS - New Devices for Reducing Pain and Improving Blood Sample Quality
SN - 978-989-8111- 64-7
AU - Wacogne B.
AU - Pieralli C.
AU - Cabodevila G.
AU - Baron N.
AU - Marioli S.
AU - Pazart L.
PY - 2009
SP - 290
EP - 295
DO - 10.5220/0001776902900295