DEVELOPING A PUPILLOMETER
Gonçalo Leal, Pedro Vieira, Carlos Neves
2009
Abstract
This project presents stable and robust optical equipment for detecting the area of the pupil and its variation on a temporal scale. An algorithm was developed to detect the pupil contour, implemented in a simple, intuitive and user friendly interface programme. Using the equipment specifically developed, measurements were taken of the area, perimeter, horizontal diameter and vertical diameter. After a statistical and comparative study, it was possible to reach conclusions regarding the general dimensions of the pupil, its variation prompted by a given stimulus and the clinical viability of the equipment concerned.
References
- Enderle, John, Susan Blanchard and Joseph Bronzino. Introduction to Biomedical Engeneering. 2th Edition. San Diego: Academic Press, 2005.
- Filipe, João A. Capão, F. Falcão Reis and J. Castro Correia. “Assessement of autonomic function in high level athletes by pupillometry”. Autonomic Neuroscience: Basic and Clinical. Vol.104. 2003, pp. 66-72.
- Gonzalez, Rafael C., Richard E. Woods and Steven L.Eddins. Digital Image Processing using MATLAB. New Jersey: Prentice Hall, 2004.
- Hachol, A., et al. “Measurement of pupil reactivity using fast pupilometry”. Physiol. Meas. Vol.28. 2007, pp. 61-72.
- Howarth, Peter A., Gordon Heron and Louise Wittaker. “ The Measurement of Pupil cycling time”. Graete's Arch Clin. Exp. Ophthalmol. Vol.238, 2000, pp. 826-832.
- Iacoviello, Daniela. “Analysis of pupil fluctuations after a light stimulus by image processing and neural network”. Computers and Mathematics with Applications. Vol.53. 2006.
- Kardon, Randy. 2003. “Pupil”. In Adler's Physiology of the Eye. Edited by Paul L. Kaufman and Albert Alm. 10th Edition. St Louis : Mosby, 713-743.
- Kim, Jieun, Kyungmo Park and Gon Khan. 2004. “A Method for Size Estimation of Amorphous Pupil in 3- Dimensional Geometry”. Paper presented at the 26th Annual International Conference of the IEEE EMBS, in San Francisco.
- Rakshit, Soumyadip and Donald M. Monro. Pupil Shape Description using Fourrier Series. 2007.
- Smith, Shirley A. and S. E. Smith. “Pupil function: tests and disorders”, in MATHIAS, Christopher J. and Sir Roger Bannister, Autonomic Failiure: A Textbook of Clinical Disorders of the Autonomic Nervous System. 4th Edition. Oxford : Oxford University Press, 2001.
Paper Citation
in Harvard Style
Leal G., Vieira P. and Neves C. (2009). DEVELOPING A PUPILLOMETER . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009) ISBN 978-989-8111- 64-7, pages 314-319. DOI: 10.5220/0001780403140319
in Bibtex Style
@conference{biodevices09,
author={Gonçalo Leal and Pedro Vieira and Carlos Neves},
title={DEVELOPING A PUPILLOMETER},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)},
year={2009},
pages={314-319},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001780403140319},
isbn={978-989-8111- 64-7},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)
TI - DEVELOPING A PUPILLOMETER
SN - 978-989-8111- 64-7
AU - Leal G.
AU - Vieira P.
AU - Neves C.
PY - 2009
SP - 314
EP - 319
DO - 10.5220/0001780403140319