SIMPLY FABRICATED PRECISE MICROFLUIDIC MIXER WITH RESIST FLOW PATHS SEALED BY AN ACRYLIC LID
Toshiyuki Horiuchi, Hiroyuki Watanabe, Naoki Hayashi, Takuya Kitamura
2010
Abstract
A microfluidic mixer was simply and easily fabricated using 380-μm thick patterns of negative resist SU-8 as flow paths and sealing the paths by an acrylic lid plate. The SU-8 was mainly composed of epoxy resin, and it was hardened by the baking after the development. Because the too narrow flow paths were not practical, the target width of the flow-path was set at 30-100 μm. The aspect ratio limit for 1:1 line-and-space patterns increased when the pattern width became large and the lower numerical-aperture or higher F-number projection lens was adopted. The maximum aspect ratio for line-and-space patterns with a width of 26-53 μm was 6.5-8, corresponding to the pattern width and the numerical aperture. After snail-shape flow-path groove patterns were successfully fabricated, the resist block was covered by an acrylic lid plate and sealed using screws. After microtubes were attached to the entrance and exit holes, red and blue colored waters were injected into the two entrance tubes. As a result, two waters were mixed while passing through the snail-shape paths, and dark purple water was ejected from the exit. It was successfully verified that the easily and simply fabricated microfluidic mixer actually worked well.
References
- Lien, K. Y., Liu, C.J., Lee, G. B., 2008. MEMS 2008, IEEE 21st International Conference on Micro Electro Mechanical Systems, 66-69.
- Lei, L., Mattos, I. L., Chen, Y., 2008. Microelectronic Engineering 85, 1318-1320.
- Casquillas, G. V., Bertholle, F., Berre, M., Meance, S., Malaquin, L., Greffet, J. J., Chen, Y., 2008. Microelectronic Engineering 85, 1367-1369.
- Tsai, N. C., Sue, Sue, C. Y., 2006. Biosensors and Bioelectronics 22, 313-317.
- Yang, R., Soper, S. A., Wang, W., 2007. Sensors and Actuators A 135, 625-636.
- Nugen, S. R., Asiello, P. J., Connelly, J. T., Baeumner, A. J., 2009. Biosensors and Bioelectronics 24, 2428- 2433.
- Kontakis, K., Petropoulos, A., Kaltsas, G., Speliotis, T., Gogolides, E., 2009. Microelectronic Engineering 86, 1382-1384.
- Lo, C. S., Prewett, P. D., Davies, G. J., Bowen, J., Vanner, K., 2008, Microelectronic Engineering 85, 1062-1065.
- Ho, L. F., Chollet, F., 2008, Microelectronic Engineering 85, 1306-1310.
- Avram, M., Iliescu, C., Volmer, M., Avram, A., 2008. Digest of Papers, Microprocesses and Nanotechnology 2008, 21st International Microprocesses and Nanotechnology Conference , 442-443.
- Eun, D. S., Kong, D. Y., Chang, S. J., Yoo, J. H., Hong, Y. M., Shin, J. K., Lee, J. H., 2008. Digest of Papers, Microprocesses and Nanotechnology 2008, 21st International Microprocesses and Nanotechnology Conference , 448-449.
- Hirota, K., Ozaki, M., Horiuchi, T., 2003. Japanese Journal of Applied Physics 42, 4031-4036.
- Horiuchi, T., Watanabe, H., 2008. Journal of Photopolymer Science and Technology 21, 77-83.
Paper Citation
in Harvard Style
Horiuchi T., Watanabe H., Hayashi N. and Kitamura T. (2010). SIMPLY FABRICATED PRECISE MICROFLUIDIC MIXER WITH RESIST FLOW PATHS SEALED BY AN ACRYLIC LID . In Proceedings of the Third International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2010) ISBN 978-989-674-017-7, pages 82-87. DOI: 10.5220/0002715100820087
in Bibtex Style
@conference{biodevices10,
author={Toshiyuki Horiuchi and Hiroyuki Watanabe and Naoki Hayashi and Takuya Kitamura},
title={SIMPLY FABRICATED PRECISE MICROFLUIDIC MIXER WITH RESIST FLOW PATHS SEALED BY AN ACRYLIC LID},
booktitle={Proceedings of the Third International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2010)},
year={2010},
pages={82-87},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002715100820087},
isbn={978-989-674-017-7},
}
in EndNote Style
TY - CONF
JO - Proceedings of the Third International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2010)
TI - SIMPLY FABRICATED PRECISE MICROFLUIDIC MIXER WITH RESIST FLOW PATHS SEALED BY AN ACRYLIC LID
SN - 978-989-674-017-7
AU - Horiuchi T.
AU - Watanabe H.
AU - Hayashi N.
AU - Kitamura T.
PY - 2010
SP - 82
EP - 87
DO - 10.5220/0002715100820087