DEVELOPMENT OF A COMPACT X-RAY PIV SYSTEM AND NEW X-RAY FLOW TRACERS - Visualization of Opaque Biofluid Flows using X-ray PIV System
Sang Joon Lee, Sung Yong Jung
2010
Abstract
A compact X-ray particle image velocimetry (PIV) system employing a medical X-ray tube as a light source was developed to obtain quantitative velocity field information of opaque flows. The X-ray PIV system consists of a medical X-ray tube, an X-ray CCD camera, a programmable shutter for generating a pulse-type X-ray beam, and a synchronization device. Through performance tests, the feasibility of the developed X-ray PIV system as a flow measuring device was verified. In applying the developed system to biofluid flows, the most important prerequisite is to develop suitable flow tracers which should be detected clearly by the X-ray imaging system. Iopamidol was encapsulated into the poly(vinyl alcohol) (PVA) microparticles to fabricate such flow tracers. The characteristics of the fabricated microparticles were checked. With increasing the amount of crosslinker, the degree of crosslinking and the efficiency of the Iopamidol encapsulation were increased. This compact X-ray PIV system is a unique and useful for investigating various biofluid flows in laboratory experiments.
References
- Adrian, R. J. (1991) “Particle-imaging techniques for experimental fluid mechanics”, Annual Review of Fluid Mechanics, Vol. 23, pp. 261-304.
- Fouras, A., Dusting, J., Lewis, R. and Hourigan, K. (2007) “Three-dimensional synchrotron X-ray particle image velocimetry”, Journal of Applied Physics, Vol. 102, 064916.
- Im, K.S., Fezzaa, K., Wang, Y. J., Liu, X., Wang, J. and Lai, M. C. (2007) “Particle tracking velocimetry using fast X-ray phase-contrast imaging”, Applied Physics Letters, Vol. 90, 091919.
- Jenneson, P. M., Gilboy, W. B., Morton, E. J. and Gregory, P. J. (2003) “An-ray micro-tomography system optimised for the low-dose study of living organisms”, Applied radiation and isotopes, Vol. 58, pp. 177-181.
- Kim, G. B. and Lee, S. J. (2006) “X-ray PIV measurements of blood flows without tracer particles”, Experiments in Fluids, Vol. 41, pp. 195-200.
- Lee, S. J. and Kim, G. B. (2003) “X-ray Particle Image Velocimetry for measuring quantitative flow information inside opaque objects”, Journal of Applied Physics, Vo. 94, pp. 3620-3623.
- Lee, S. J. and Kim, S. (2005) “Simultaneous measurement of size and velocity of microbubbles moving in an opaque tube using an X-ray particle tracking velocimetry technique”, Experiments in Fluids, Vol. 39, pp. 492-497.
- Lee, S. J. and Kim, Y. M. (2008) “In vivo Visualization of the Water-refilling Process in Xylem Vessels Using Xray Micro-imaging”, Annals of Botany, Vol. 101, pp. 595-602.
- Malek, A., Alper, S. and Izumo, S. (1999) “Hemodynamic shear stress and its role in atherosclerosis”, JAMA, Vol. 282, pp. 2035-2042.
- Matsumura, S., Kurita, H. and Shimokobe, H. (1993) “Anaerobic biodegradability of polyvinyl alcohol”, Biotechnology Letters, Vol. 15, pp. 749-754.
- Matsumura, S., Takahashi, J., Maeda, S. and Yoshikawa, S. (1988) “Molecular design of biodegradable functional polymers, 1. Poly(sodium vinyloxyacetate)”, Die Makromolekulare Chemie, Rapid Communications, Vol. 9, pp. 1-5.
- Nord, F. F. (1936) “Dehydrogenation activity of Fusarium lini B”, Naturwissenschaften, Vol. 24, 763.
- Pahernik, S., Griebel, J., Botzlar, A., Gneiting, T., Brandl, M., Dellian, M. and Goetz, A.E. (2001) “Quantitative imaging of tumour blood flow by contrast-enhanced magnetic resonance imaging”, British Journal of Cancer, Vol. 85, pp. 1655-1663.
- Rhode K.S., Lambrou T., Hawkes D.J. and Seifalian A.M. (2005) “Novel approaches to the measurement of arterial blood flow from dynamic digital x-ray images”, IEEE TRANSACTIONS ON MEDICAL IMAGING, Vol. 24, pp. 500-513.
Paper Citation
in Harvard Style
Lee S. and Jung S. (2010). DEVELOPMENT OF A COMPACT X-RAY PIV SYSTEM AND NEW X-RAY FLOW TRACERS - Visualization of Opaque Biofluid Flows using X-ray PIV System . In Proceedings of the Third International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2010) ISBN 978-989-674-017-7, pages 32-37. DOI: 10.5220/0002738100320037
in Bibtex Style
@conference{biodevices10,
author={Sang Joon Lee and Sung Yong Jung},
title={DEVELOPMENT OF A COMPACT X-RAY PIV SYSTEM AND NEW X-RAY FLOW TRACERS - Visualization of Opaque Biofluid Flows using X-ray PIV System},
booktitle={Proceedings of the Third International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2010)},
year={2010},
pages={32-37},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002738100320037},
isbn={978-989-674-017-7},
}
in EndNote Style
TY - CONF
JO - Proceedings of the Third International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2010)
TI - DEVELOPMENT OF A COMPACT X-RAY PIV SYSTEM AND NEW X-RAY FLOW TRACERS - Visualization of Opaque Biofluid Flows using X-ray PIV System
SN - 978-989-674-017-7
AU - Lee S.
AU - Jung S.
PY - 2010
SP - 32
EP - 37
DO - 10.5220/0002738100320037