CLASSIFICATION OF POWER QUALITY DISTURBANCES VIA HIGHER-ORDER STATISTICS AND SELF-ORGANIZING NEURAL NETWORKS
Juan José González de la Rosa, José Carlos Palomares, Agustín Agüera, Antonio Moreno Muñoz
2010
Abstract
This work renders the classification of Power Quality (PQ) disturbances using fourth-order sliding cumulants’ maxima as the key feature. These estimators are calculated over high-pass filtered real-life signals, to avoid the low-frequency 50-Hz sinusoid. Four types of electrical AC supply anomalies constitute the starting grid of a competitive layer performance, which manages to classify 90 signals within a 2D-space (whose coordinates are the minima and the maxima of the sliding cumulants calculated over each register). Four clusters have been clearly identified via the competitive network, each of which corresponds to a type of anomaly. Then, a Self-Organizing Network is conceived in order to guess additional classes in the feature space. Results suggest the idea of two additional sets of signals, which are more related to the degree of signals’ degeneration than to real new groups of anomalies. We collaterally conclude the need of additional features to face the problem of subclass division. The experience sets the foundations of an automatic procedure for PQ event classification.
References
- (1995a). IEEE Guide for service to equipment sensitive to momentary voltage disturbances. Technical Report IEEE Std. 1250-1995, The Institute of Electrical and Electronics Engineers, Inc.
- (1995b). IEEE Recommended practice for monitoring electric power quality. Technical Report IEEE Std. 1159-1995, The Institute of Electrical and Electronics Engineers, Inc.
- Bollen, M. H. J., Styvaktakis, E., and Gu, I. Y.-H. (2005). Categorization and analysis of power system transients. IEEE Transactions on Power Delivery, 20(3):105-118.
- Mendel, J. M. (1991). Tutorial on higher-order statistics (spectra) in signal processing and system theory: Theoretical results and some applications. Proceedings of the IEEE, 79(3):278-305.
- Moreno, A., Flores, J., Oterino, D., and De la Rosa, J. J. G. (2007). Power line conditioner based on ca pwm chopper. In ISIE 2007, Proceedings of the 2007 IEEE International Symposium on Industrial Electronics, pages 2454-2456, June 2007.
- Moreno, A. and et al (2007). Mitigation Technologies in a Distributed Environment. Power Systems. SpringerVerlag, 1 edition.
- Nikias, C. L. and Mendel, J. M. (1993). Signal processing with higher-order spectra. IEEE Signal Processing Magazine, pages 10-37.
- Omer Nezih Gerek and Ece, D. G. (2006). Powerquality event analysis using higher order cumulants and quadratic classifiers. IEEE Transactions on Power Delivery, 21(2):883-889.
- Paul, D. (2001). Low-voltage power system surge overvoltage protection. IEEE Transactions on Industry Applications, 37(1):223-229.
- De la Rosa, J. J. G., Lloret, I., Puntonet, C. G., and Górriz, J. M. (2004). Higher-order statistics to detect and characterise termite emissions. Electronics Letters, 40(20):1316-1317. Ultrasonics.
- De la Rosa, J. J. G., Lloret, I., Puntonet, C. G., Piotrkowski, R., and Moreno, A. (2008). Higher-order spectra measurement techniques of termite emissions. a characterization framework. Measurement (Ed. Elsevier), 41(1):105-118. Available online 13 October 2006.
- De la Rosa, J. J. G., Moreno, A., and Puntonet, C. G. (2007). A practical review on higher-order statistics interpretation. application to electrical transients characterization. Dynamics of continous discrete and Impulsive Systems-Series B: Applications and Algorithms, 14(4):1577-1582.
- De la Rosa, J. J. G. and Mun˜oz, A. M. (2009). Higherorder characterization of power quality transients and their classification using competitive layers. Przega¸d Elektrotechniczny-Electrical Review, 10(Issue 85):284-289.
- De la Rosa, J. J. G., Mun˜oz, A. M., Gallego, A., Piotrkowski, R., and Castro, E. (2009). Higher-order characterization of power quality transients and their classification using competitive layers. Measurement (Ed. Elsevier), 42(Issue 3):478-484.
Paper Citation
in Harvard Style
José González de la Rosa J., Carlos Palomares J., Agüera A. and Moreno Muñoz A. (2010). CLASSIFICATION OF POWER QUALITY DISTURBANCES VIA HIGHER-ORDER STATISTICS AND SELF-ORGANIZING NEURAL NETWORKS . In Proceedings of the 7th International Conference on Informatics in Control, Automation and Robotics - Volume 3: ICINCO, ISBN 978-989-8425-02-7, pages 183-190. DOI: 10.5220/0002915101830190
in Bibtex Style
@conference{icinco10,
author={Juan José González de la Rosa and José Carlos Palomares and Agustín Agüera and Antonio Moreno Muñoz},
title={CLASSIFICATION OF POWER QUALITY DISTURBANCES VIA HIGHER-ORDER STATISTICS AND SELF-ORGANIZING NEURAL NETWORKS},
booktitle={Proceedings of the 7th International Conference on Informatics in Control, Automation and Robotics - Volume 3: ICINCO,},
year={2010},
pages={183-190},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002915101830190},
isbn={978-989-8425-02-7},
}
in EndNote Style
TY - CONF
JO - Proceedings of the 7th International Conference on Informatics in Control, Automation and Robotics - Volume 3: ICINCO,
TI - CLASSIFICATION OF POWER QUALITY DISTURBANCES VIA HIGHER-ORDER STATISTICS AND SELF-ORGANIZING NEURAL NETWORKS
SN - 978-989-8425-02-7
AU - José González de la Rosa J.
AU - Carlos Palomares J.
AU - Agüera A.
AU - Moreno Muñoz A.
PY - 2010
SP - 183
EP - 190
DO - 10.5220/0002915101830190