A SENSORIZED PLATFORM TO MONITOR AND REGULATE VAD FUNCTIONALITIES - Wearable and Implantable Devices to Improve VAD Performances and Extend its Field of Application
N. Taccini, M. Nannizzi, C. Ciaponi, P. Valdastri, P. Dario
2011
Abstract
A novel system to control Ventricular Assist Device (VAD) is under study in the frame of the project SENSORART (FP7-ICT-248763, funded by the European Commission). The SensorART platform will be open, interoperable, extendable and VAD-independent and it will incorporate different hardware and software components in order to improve both the quality of the patients’ treatment and the workflow of the specialists. In the frame of this project a set of implantable sensors will be identified, developed and/or adapted for long term implant, in order to gather all the necessary information to control the VAD functionalities by a wearable hardware unit. Wearable sensors will be studied to assist the decision algorithms by gathering physiological parameters using non invasive approach. Purpose of this paper is to give a brief description of the system under study and describe the preliminary activity performed during the developing of the implantable and wearable sensors. In particular, the evaluation and calibration of a novel catheter pressure sensor is reported and the results of the feasibility of a tonometry wearable system is described.
References
- Bour, J. and Kellett, J. (2008). Impedance cardiography: a rapid and cost-effective screening tool for cardiac disease. In Eur J Intern Med., volume Epub 2008 Feb 11.
- Bullister, E., Reich, S., and Entremont, P. (2001). A blood pressure sensor for long-term implantation. artificial organs. In Artificial Organs, volume 25(5), pages 376-379.
- Chemla, D., Teboul, J., and Richard, C. (2008). Non invasive assessment of arterial pressure. In Curr Opin Crit Care, volume 14(3), pages 317-321.
- Maeda, K., Chinzei, T., Imachi, K., and et al. (1988). Predictive control by physical activity rate of a total artificial heart during exercise. In ASAIO Transaction, volume 34, pages 480-484.
- Nakamura, M., Homma, A., Tatsumi, E., and et al. (2000). Mixed venous oxygen saturation as a promising parameter for the physiologic control of the artificial heart. In ASAIO J, pages 761-766.
- Valdastri, P., Rossi, S., Menciassi, A., Lionetti, V., Bernini, F., Recchia, F., and Dario, P. (2008). An implantable zigbee ready telemetric platform for in vivo monitoring of physiological parameters. Sensors and Actuators, Volume 142:369-378.
- Waters, T., Allaire, P., Tao, G., and et al. (1999). Motor feedback physiological control for a continuous flow ventricular assist device. In Artificial Organs, volume 23(6), pages 480-487.
Paper Citation
in Harvard Style
Taccini N., Nannizzi M., Ciaponi C., Valdastri P. and Dario P. (2011). A SENSORIZED PLATFORM TO MONITOR AND REGULATE VAD FUNCTIONALITIES - Wearable and Implantable Devices to Improve VAD Performances and Extend its Field of Application . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011) ISBN 978-989-8425-37-9, pages 315-318. DOI: 10.5220/0003132103150318
in Bibtex Style
@conference{biodevices11,
author={N. Taccini and M. Nannizzi and C. Ciaponi and P. Valdastri and P. Dario},
title={A SENSORIZED PLATFORM TO MONITOR AND REGULATE VAD FUNCTIONALITIES - Wearable and Implantable Devices to Improve VAD Performances and Extend its Field of Application},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)},
year={2011},
pages={315-318},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003132103150318},
isbn={978-989-8425-37-9},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)
TI - A SENSORIZED PLATFORM TO MONITOR AND REGULATE VAD FUNCTIONALITIES - Wearable and Implantable Devices to Improve VAD Performances and Extend its Field of Application
SN - 978-989-8425-37-9
AU - Taccini N.
AU - Nannizzi M.
AU - Ciaponi C.
AU - Valdastri P.
AU - Dario P.
PY - 2011
SP - 315
EP - 318
DO - 10.5220/0003132103150318