DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION - A New Device for Hemodynamic Parameters Assessment
H. C. Pereira, J. B. Simoes, J. L. Malaquias, T. Pereira, V. Almeida, E. Borges, J. Cardoso, C. Correia
2011
Abstract
The present work proposes a new device for local pulse wave velocity (PWV), by using an innovative configuration of a double piezoelectric (PZ) sensor probe. PWV is assessed in one single location and involves the determination of time delay, between the signals acquired simultaneously by two PZs, 23 mm apart. The double probe (DP) is characterized in a dedicated test bench system, where two main studies were carried out. In the first one, the impulse response (IR) for each PZ sensor is determined and evaluated through the deconvolution method. In the second one, DP time resolution is estimated from a set of time delay algorithms and compared with the reference values, obtained through the signals of two pressure sensors. Results demonstrate the effectiveness of the inferred IRs in deconvolution purposes and the possibility of measure higher PWV values (≈ 19m/s), through the DP, with an error less than 10%.
References
- Hermeling E, Reesink K, Reneman R and Hoeks A 2008 Confluence of incident and reflected waves interferes with systolic foot detection of the carotid artery distension waveform J Hypertens. 26 2374-80
- Laurent S., Cockcroft J., Van Bortel L., Boutouyrie P., Giannattasio C, Hayoz D, et al. 2006 Expert consensus document on arterial stiffness: methodological issues and clinical applications Eur Heart J. 27 2588-2605
- Meinders J., Kornet L., Brands P. and Hoeks A. 2001 Assessment of local pulse wave velocity in arteries using 2D distension waveforms Ultrason. Imaging 23 199-215
- Pereira H. C., Cardoso J. M., Almeida V. G., Pereira T., Borges E., Figueiras E., Ferreira L.R., Simões J., Correia C. 2009 Programmable testbench for hemodynamic studies IFMBE Proceedings 25/IV 1460ff
- Pereira, H. C., Lopes, T., Almeida, V., Borges, E., Figueiras, E., Basílio J. B., Cardoso, J., and Correia C., 2010 Characterization of a double probe for local pulse wave velocity assessment Physiol Meas. 31 697-714
- Segers P., Kips J., Trachet B., Swillens A., Vermeersch S., Mahieu D., Rietzchel E., Buyzere M. and Bortel L. 2009 Limitations and pitfalls of non-invasive measurement of arterial pressure wave reflections and pulse wave velocity Artery Research 3 79-88
Paper Citation
in Harvard Style
Pereira H., Simoes J., Malaquias J., Pereira T., Almeida V., Borges E., Cardoso J. and Correia C. (2011). DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION - A New Device for Hemodynamic Parameters Assessment . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011) ISBN 978-989-8425-37-9, pages 444-447. DOI: 10.5220/0003293704440447
in Bibtex Style
@conference{biodevices11,
author={H. C. Pereira and J. B. Simoes and J. L. Malaquias and T. Pereira and V. Almeida and E. Borges and J. Cardoso and C. Correia},
title={DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION - A New Device for Hemodynamic Parameters Assessment},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)},
year={2011},
pages={444-447},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003293704440447},
isbn={978-989-8425-37-9},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)
TI - DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION - A New Device for Hemodynamic Parameters Assessment
SN - 978-989-8425-37-9
AU - Pereira H.
AU - Simoes J.
AU - Malaquias J.
AU - Pereira T.
AU - Almeida V.
AU - Borges E.
AU - Cardoso J.
AU - Correia C.
PY - 2011
SP - 444
EP - 447
DO - 10.5220/0003293704440447