NANOSTRUCTURED VS. CARBONACEOUS BIOSENSORS - Comparative Studies for Detection of Phenolic Compounds

Constantin Apetrei, Jose Antonio de Saja, Maria Luz Rodriguez-Mendez

2012

Abstract

The biosensing properties of tyrosinase biosensors were investigated for two different immobilization matrixes: carbon paste and Langmuir-Blodgett thin film. In both cases the electron mediator was the lutetium (III) bisphthalocyaninate. The electrochemical responses of biosensors towards phenol and catechol were analyzed and compared. The tyrosinase maintains its bioactivity well within the immobilization matrices. A clearly defined reduction current proportional to the phenolic compounds concentration was observed in cyclic voltammetry, which attributed to the reduction of enzymatically produced quinone at the electrode surface. It was demonstrated that the biosensor based on Langmuir-Blodgett thin film shows the best performances in terms of kinetics and detection limit for the phenolic compounds analyzed.

References

  1. Ameer, Q., Adeloju, S. B., 2009. Sens. Actuators B 140, 5-11.
  2. Apetrei, C., Alessio, P., Constantino, C. J. L., de Saja, J. A., Rodriguez-Mendez, M. L., Pavinatto, F. J., Fernandes, E. G., Zucolotto, V., Oliveira, O. N., 2011. Biosens. Bioelectronics 26, 2513-2519.
  3. Bard, A. J., Faulkner, L. R., 2001. Electrochemical Methods, John Wiley and Sons, New York.
  4. Bukowska, B., Kowalska, S., 2004. Toxicol. Lett., 152, 73-84.
  5. Cabaj, J., Soloducho, J., Nowakowska-Oleksy, A., 2010. Sens. Actuat. B, 143, 508-515.
  6. Carralero, V., Mena, M. L., Gonzalez-Cortes, A., YanezSedeno, P., Pingarron, J. M., 2006. Biosens. Bioelectron., 22, 730-736.
  7. Cosnier, S., Szunerits, S., Marks, R. S., Lellouche, J., Perie, K., 2001. J. Biochem. Biophys. Methods, 50, 65-77.
  8. de Saja, J. A., Rodríguez-Méndez, M. L., 2005. Adv. Colloid Interf. Sci. 116, 1 -11.
  9. Granero, A.M., Fernández, H., Agostini, E., Zón, M. A., 2010. Talanta 83, 249-255.
  10. Hill, M. K., 2004. Understanding environmental pollution, Cambridge University Press, UK.
  11. Kazandjian, R., Klibanov, A., 1985. J. Am. Chem. Soc. 107, 5448-5450.
  12. Kiralp, S., Toppare, L., 2006. Process Biochem. 41 236- 239.
  13. Kovács, A., Mörtl, M., Kende, A., 2011. Microchem. J., 99, 125-131.
  14. Kumar Vashist, S., Zheng, D. Al-Rubeaan, K., Luong, J.H.T., Sheu, F.S., 2011. Biotechnol. Adv. 29, 169- 188.
  15. Ma, Y., Yang, C., Li, N., Yang, X., 2005. Talanta, 67, 979-983.
  16. Manahan S. E., 1991. Environmental Chemistry, Lewis Publishers, New York.
  17. Moldoveanu, S.C., Kiser, M., 2007. J. Chromatography A, 1141, 90-97.
  18. Palmer, T., 1991.Understanding Enzymes, PrenticeHall/Ellis Horwood, London.
  19. Pavinatto, F. J., Fernandes, E. G. R., Alessio, P., Constantino, C. J. L., de Saja, J. A., Zucolotto, V., Apetrei, C., Oliveira Jr., O. N., Rodriguez-Mendez M. L., 2011. J. Mater. Chem. 21, 4995-5003.
  20. Roberts, G. G., 1990. Langmuir Blodgett Films, Plenum, New York.
  21. Rogers, K. R., Becker, J. Y., Cembrano, J., Chough, S.H., 2001. Talanta 54, 1059-1065.
  22. Shiddiky, M. J. A., Torriero, A. A. J., 2011. Biosens. Bioelectronics 26, 1775-1787.
  23. Shu, F. R., Wilson G. S., 1976. Anal. Chem. 48, 1679- 1686.
  24. Tsai, Y., Chiu, C., 2007. Sens. Actuators B, 125, 10-16.
  25. Yin, H., Zhou, Y., Xu, J., Ai, S., Cui, L., Zhu, L., 2010. Anal. Chim. Acta 659, 144-150.
  26. Zejli, H., Hidalgo-Hidalgo de Cisneros, J. L., NaranjoRodriguez, I., Liu, B., Temsamani, K. R., Marty, J. L., 2008. Anal. Chim. Acta 612, 198-203.
Download


Paper Citation


in Harvard Style

Apetrei C., de Saja J. and Rodriguez-Mendez M. (2012). NANOSTRUCTURED VS. CARBONACEOUS BIOSENSORS - Comparative Studies for Detection of Phenolic Compounds . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2012) ISBN 978-989-8425-91-1, pages 104-109. DOI: 10.5220/0003716701040109


in Bibtex Style

@conference{biodevices12,
author={Constantin Apetrei and Jose Antonio de Saja and Maria Luz Rodriguez-Mendez},
title={NANOSTRUCTURED VS. CARBONACEOUS BIOSENSORS - Comparative Studies for Detection of Phenolic Compounds},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2012)},
year={2012},
pages={104-109},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003716701040109},
isbn={978-989-8425-91-1},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2012)
TI - NANOSTRUCTURED VS. CARBONACEOUS BIOSENSORS - Comparative Studies for Detection of Phenolic Compounds
SN - 978-989-8425-91-1
AU - Apetrei C.
AU - de Saja J.
AU - Rodriguez-Mendez M.
PY - 2012
SP - 104
EP - 109
DO - 10.5220/0003716701040109