INCUBATION TYPE PLANAR PATCH CLAMP BIOSENSOR - Basic Performances

Tsuneo Urisu, Hidetaka Uno, Zhi-Hong Wang, Senthil Kumar Obuliraj, Noriko Takada, Masaki Aoyama, Mitsukazu Suzui, Toshifumi Asano, Toru Ishizuka, Hiromu Yawo

2012

Abstract

The biosensors based on the incubation type planar patch clamp method was developed and the basic properties were investigated. Usefulness of light-gated ionchannel method on the performance of the device was confirmed. The excess current noise and the thermal noise due to the micropore resistance and the seal resistance were the main sources of the noise, and the noise level of the developed biosensor was 7 pA at the 1 kHz low pass filter. This value is slightly larger than the single ionchannel current level (~4pA) of TRPV1. We consider that the developed device has a sufficient performance for the whole cell measurements, and extremely suitable for the high throughput screening application with neural network, in which incubation function is essentially necessary.

References

  1. Bayley, H., Cremer, P.S., 2001. Nature 413, 226.
  2. Caterina, M. J., Schumacher, M. A., Tominaga, M., Rosen, T. A., Levine, J. D., Julius, D., 1997. Nature 389, 816.
  3. Erickson, J., Tooker, A., Tai, Y. C., Pine, J., 2008., Journal of Neuroscience Methods 175, 1.
  4. Fertig, N., Blick, R. H., Behrends, J. C., 2002. Biophys. J. 82,3056.
  5. Li, X. H., Klemic, K. G., Reed, M. A., Fred, J., Sigworth, F. J. 2006. Nano Letters 6 , 815.
  6. Matthews, B., Jack, W., 2006. J. Microelectromech. 15 214.
  7. Mayer, M., Kriebel, J. K., Tosteson, M. T., Whitesides, G. M., 2003. Biophysical J. 85, 2684.
  8. Pantoja, R., Nagarah, J. M., Starace, D. M., Melosh, N. A. Blunck, R., Bezanilla, F., Heath, J. R., 2004. Biosens. Bioelectron. 20, 509.
  9. Petreanu, L., Huber, D., Sobczyk, A., Svoboda, K., 2007, Nature Neurosci. 10, 663.
  10. Reska, A., Gasteier, P., Schulte, P., Moeller, M., Offenhäusser, A., Groll, J., 2008. Advanced Materials 20,2751.
  11. Sett, A, Burkhardt, C., Weber, U., Stiphout, P.V., Knott, T. 2003. Receptors and Channels 9, 59.
  12. Sordel, T., Garnier-Raveaud, S., Sauter, F., Pudda, C., F. Marcel, F., Waard, M. D., Arnoult, C., Vivaudou, M., Chatelain, F., Picollet-D'hahan, N., 2006. J. Biotechnol. 125, 142.
  13. Tao, H. W., Zhang, L. I., Bi, G., Poo, M., 2000. J. Neurosci. 20, 3233.
  14. Taylor, A. M., Dieterich, D. C., Ito, H. T., Kim, S. A., Schuman, E. M. 2010. Neuron 66, 57.
Download


Paper Citation


in Harvard Style

Urisu T., Uno H., Wang Z., Obuliraj S., Takada N., Aoyama M., Suzui M., Asano T., Ishizuka T. and Yawo H. (2012). INCUBATION TYPE PLANAR PATCH CLAMP BIOSENSOR - Basic Performances . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2012) ISBN 978-989-8425-91-1, pages 143-148. DOI: 10.5220/0003764301430148


in Bibtex Style

@conference{biodevices12,
author={Tsuneo Urisu and Hidetaka Uno and Zhi-Hong Wang and Senthil Kumar Obuliraj and Noriko Takada and Masaki Aoyama and Mitsukazu Suzui and Toshifumi Asano and Toru Ishizuka and Hiromu Yawo},
title={INCUBATION TYPE PLANAR PATCH CLAMP BIOSENSOR - Basic Performances},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2012)},
year={2012},
pages={143-148},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003764301430148},
isbn={978-989-8425-91-1},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2012)
TI - INCUBATION TYPE PLANAR PATCH CLAMP BIOSENSOR - Basic Performances
SN - 978-989-8425-91-1
AU - Urisu T.
AU - Uno H.
AU - Wang Z.
AU - Obuliraj S.
AU - Takada N.
AU - Aoyama M.
AU - Suzui M.
AU - Asano T.
AU - Ishizuka T.
AU - Yawo H.
PY - 2012
SP - 143
EP - 148
DO - 10.5220/0003764301430148