12 GHz CMOS MEMS Lab-on-chip System for Detection of Concentration of Suspended Particles in Bio-suspensions

Subhajit Guha, Marco Lisker, Andreas Trusch, Alexander Wolf, Chafik Meliani, Christian Wenger

2015

Abstract

This work presents a high frequency (X-band) CMOS dielectric sensor with hybrid microfluidic integration, applied to biosensing techniques; primarily to detect concentration of suspended particles in a solution. The detection technique is based on capacitive sensing of varying permittivity of the aqueous solution caused by different concentrations of suspended particles. The sensor chip is fabricated in 0.25 µm SiGe:C BiCMOS technology of IHP with post processed PDMS microfluidic hybrid integration. The operating frequency of the sensor is 12.3 GHz and draws a DC power of approximately 35 mW from 3 V power supply. The dielectric sensitivity of the chip was characterized and calibrated using different organic fluids (alcohols); a sensitivity of 100 MHz/permittivity was measured with the sensor. After the calibration phase, the sensor was further used to measure the concentration of glucose in a homogeneous glucose solution. Frequency down-shift of 250 MHz/10% increase in water concentration in the homogeneous solution was observed. In order to analyse the concentration of suspended particles in a solution various concentrations of micro-beads in acetone solution were measured. Approximately a frequency up-shift of 125 MHz/10 µl increase in bead volume in acetone was observed. The overall chip size is 2.76 mm2.

References

  1. Pires, N.M.M, Dong, T., Hanke, U., Hoivik, N. (2014) Recent Developments in Optical detection technologies in Lab-On-a-Chip Devices for Biosensing Application. Sesnors.14. p. 15458-15479.
  2. Goh, S., and Ram, R.J. (2010) Impedance spectroscopy for in situ biomass measurements in microbioreactor. 14th International conference on Miniaturized Systems and Life Sciences. Netherlands. p. 1556-1558.
  3. Krommenhoek, E.E., Gardeniers, J., Bomer, J., Van den Berg, A., Li, X., Ottens, M., van der Wielen, L., van Dedem, G., Van Leeuwen, M., van Gulik, W., Heijnen, J. (2006) Monitoring of yeast cell concentration using micromachined impedance sensor, Sensors and Actuators,B. 115.p. 384-389.
  4. Faenza, A., Bocchi, M., Pecorari, N., Franchi, E., Guerrieri, R.(2012) Impedance measurement technique for high sensitivity cell detection in microstructures with non-uniform conductivity distribution. Lab Chip 12(11). P.2046-2052.
  5. Rassaei, L., Goluch, E.D., Lemay, S. (2012). Substrate dependent kinetics in tyrosinase-based biosensing: Amperometry vs Spectrophotometry. Analytical and Bioanalytical Chemistry. 493. p.1577-1584.
  6. Grenier, K., Dubuc, D., Chen, T., Artis, F., Chretiennot, T., Poupot, M., and Fournié, J-J. (2013). Recent Advances in Microwave-based Dielectric Spectroscopy at the Cellular Level for Cancer Investigations IEEE-TMTT 61(4).p. 2023-2030.
  7. Ferrier, G.A., Romanuik, S.F., Thomson, D.J., Bridges, G.E., Freeman, M.R. (2009). A microwave interferometric system for simultaneous actuation and detection of single biological cells. Lab on a Chip. 9. p. 3406- 3412.
  8. Yang, Y., Zhang, H., Zhu, J., Wang, G., Tzeng, T.-R., Xuan, X., Huang, K., Wang, P. (2010). Distinguishing the viability of a single yeast cell with an ultrasensitive radio frequency sensor. Lab on a Chip. 10. p. 553-555.
  9. Guha, S., Jamal, F.I., Schmalz, K., Wenger, Ch., Meliani, Ch. (2013). CMOS lab on a chip device for dielectric characterization of cell suspensions based on a 6 GHz Oscillator. European Microwave Conference, Germany.
  10. Guha, S., Jamal, F.I., Schmalz, K., Wenger, Ch., Meliani, Ch. (2014) An 8 GHz CMOS Near Field Bio-sensor Array for Imaging Spatial Permittivity Distribution of Biomaterials. IEEE MTT-S, Interantional Microwave Symposium, USA.
  11. T.Lee (1998) The design of CMOS Radio Frequency Integrated Circuits,Cambridge.
  12. Lisker, M. Trusch, A., Fraschke, M., Kulse, P., Borokhovych, Y., Tillack, B., Ostermay, I., Krämer, T., Schmückle, F.-J., Krüger, O., Krozer, V., Heinrich, W. (2013). InP-Si BiCMOS Heterointegration Using a Substrate Transfer Process ECS Transactions. 53(245).
  13. Belrhiti, M.D., Bri, S., Nakheli, A., Haddad, M., Mamouni, A. (2012). Dielectric constant determination of liquid using rectangular waveguide structure combined with EM simulation. J.Mater.Environ.Sci. 3.p. 575-584.
  14. Kuang, W., Nelson, S.O. (1997). Dielectric relaxation charcterization of fresh fruits and vegetables from 3 to 20 GHz. J. of Micrwave power and electromagnetic energy. 32. p. 114-122.
  15. Meriakri, V V., Chigrai, E E., Kim, D., Nikitin, I.P., Pangonis, L.I., Parkhomenko, M.P., Won, J.H. (2006). Dielectric properties of glucose solutions in the millimetre-wave range and control of glucose content in blood. IOP, Meas. Sci. Technology. 18.p. 1-6.
  16. Basey-Fisher, T.H., Hanham, S.M., Maier,S.A., Stevens, M.M., Alford, N.M., Klein, N.( 2011).Microwave relaxation analysis of Dissolved Proteins:Towards free solution biosensing. Applied Physics Letters 99.
Download


Paper Citation


in Harvard Style

Guha S., Lisker M., Trusch A., Wolf A., Meliani C. and Wenger C. (2015). 12 GHz CMOS MEMS Lab-on-chip System for Detection of Concentration of Suspended Particles in Bio-suspensions . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2015) ISBN 978-989-758-071-0, pages 49-57. DOI: 10.5220/0005219300490057


in Bibtex Style

@conference{biodevices15,
author={Subhajit Guha and Marco Lisker and Andreas Trusch and Alexander Wolf and Chafik Meliani and Christian Wenger},
title={12 GHz CMOS MEMS Lab-on-chip System for Detection of Concentration of Suspended Particles in Bio-suspensions},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2015)},
year={2015},
pages={49-57},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0005219300490057},
isbn={978-989-758-071-0},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2015)
TI - 12 GHz CMOS MEMS Lab-on-chip System for Detection of Concentration of Suspended Particles in Bio-suspensions
SN - 978-989-758-071-0
AU - Guha S.
AU - Lisker M.
AU - Trusch A.
AU - Wolf A.
AU - Meliani C.
AU - Wenger C.
PY - 2015
SP - 49