Comparison of a Sensorized Garment and Activity Trackers with a Mobile Ergospirometry System Concerning Energy Expenditure
Sven Feilner, Andreas Huber, Christian Sauter, Dirk Weishäupl, Michael Hettchen, Wolfgang Kemmler, Christian Weigand, Christian Hofmann
2016
Abstract
Energy expenditure is an important parameter during the performance of physical activity. An algorithm is presented calculating the burnt calories by three given parameters: heart rate, respiration rate and movement. These three vital parameters are provided by the FitnessSHIRT system which was developed by the Fraunhofer IIS. A study was performed to compare the calculated values of the energy expenditure with a reference system based on ergospirometry, an on-body monitoring system and two commercially available activity trackers. Compared to the reference system the developed algorithm, based on the parameters derived by the FitnessSHIRT, reaches a deviation of 18.0 % during running and 18.9 % during cycling.
References
- BodyMedia (2015). The sensewear armband.
- CareFusion (2015). Oxycon mobile device.
- FitBit (2015). Fitbit activity tracker.
- Hofmann, C. (2015). Fitnessshirt: Improving safety through telemonitoring.
- InBody (2015). Inbody770.
- Kent, M. (1997). Food and Fitness: A Dictionary of Diet and Exercise. Oxford University Press, 1st edition.
- Mueller, C., Winter, C., and Rosenbaum, D. (2010). Current objective techniques for physical activity assessment in comparison with subjective methods. In Deutsche Zeitschrift fuer Sportmedizin.
- Mueller, R. (2001). Atmung, stoffwechsel und blutkreislauf. Praxis der Naturwissenschaften - Physik in der Schule, pages 23-26.
- Nißen, M. (2013). Quantified Self - An Exploratory Study on the Profiles and Motivations of Self-Tracking . Karlsruhe Institute of Technology (KIT).
- Shafer, G. et al. (1976). A mathematical theory of evidence, volume 1. Princeton university press Princeton.
- Tantinger, D., Feilner, S., Schmitz, D., and Weigand, C. (2012). Evaluation of qrs detection algorithm implemented for mobile applications based on ecg data acquired from sensorized garments. In Biomedical Engineering / Biomedizinische Technik Band 57, Heft SI-1 Track-F.
- WHO (2015). Obesity and overweight. Fact sheet No. 311.
Paper Citation
in Harvard Style
Feilner S., Huber A., Sauter C., Weishäupl D., Hettchen M., Kemmler W., Weigand C. and Hofmann C. (2016). Comparison of a Sensorized Garment and Activity Trackers with a Mobile Ergospirometry System Concerning Energy Expenditure . In Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 4: BIOSIGNALS, (BIOSTEC 2016) ISBN 978-989-758-170-0, pages 232-238. DOI: 10.5220/0005707502320238
in Bibtex Style
@conference{biosignals16,
author={Sven Feilner and Andreas Huber and Christian Sauter and Dirk Weishäupl and Michael Hettchen and Wolfgang Kemmler and Christian Weigand and Christian Hofmann},
title={Comparison of a Sensorized Garment and Activity Trackers with a Mobile Ergospirometry System Concerning Energy Expenditure},
booktitle={Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 4: BIOSIGNALS, (BIOSTEC 2016)},
year={2016},
pages={232-238},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0005707502320238},
isbn={978-989-758-170-0},
}
in EndNote Style
TY - CONF
JO - Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 4: BIOSIGNALS, (BIOSTEC 2016)
TI - Comparison of a Sensorized Garment and Activity Trackers with a Mobile Ergospirometry System Concerning Energy Expenditure
SN - 978-989-758-170-0
AU - Feilner S.
AU - Huber A.
AU - Sauter C.
AU - Weishäupl D.
AU - Hettchen M.
AU - Kemmler W.
AU - Weigand C.
AU - Hofmann C.
PY - 2016
SP - 232
EP - 238
DO - 10.5220/0005707502320238