Physiological Data Validation of the Hexoskin Smart Textile

N. H. Cherif, N. H. Cherif, N. Mezghani, N. Mezghani, N. Gaudreault, Y. Ouakrim, Y. Ouakrim, I. Mouzoune, I. Mouzoune, P. Boulay

2018

Abstract

The aim of this study is to validate cardiorespiratory function measurement of a healthy population provided by a wearable textile during a progressive maximal exercise test. The following measurements were collected using embedded sensors to assess three variables: heart rate (HR), breathing rate (BR) and ventilation (Ve). These variables were recorded simultaneously by the wearable textile and using as a reference system for a comparison purpose. The validation was performed based on the two systems agreement estimation by calculating the intraclass correlation coefficient (ICC), the concordance correlation coefficient (CCC) and the Bland-Altman plot for each variable. Twenty-eight healthy volunteers participated in this study. Analysis of each participant under exercise condition by the two measurement systems revealed high CCC values (rho_c between 0.91 and 0.99), no deviation from the 45 degrees line (C_b between 0.96 and 0.99) and significant ICC values (rho between 0.91 and 0.99, p< 0.05) for HR and BR. The Bland Altman plot for HR and BR indicated no deviation of the mean difference from zero and a small variability with tight agreement limits. However, the analysis of the estimated ventilation Ve of each participant revealed doubtful values for the CCC (rho_c between 0.2 and 0.99) and ICC (rho between 0.11 and 0.99). In summary, the Hexoskin presented good agreement for HR and BR. However, for ventilation, it is difficult to conclude from the results due to variability.}

Download


Paper Citation


in Harvard Style

Cherif N., Mezghani N., Gaudreault N., Ouakrim Y., Mouzoune I. and Boulay P. (2018). Physiological Data Validation of the Hexoskin Smart Textile. In Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2018) - Volume 1: BIODEVICES; ISBN 978-989-758-277-6, SciTePress, pages 150-156. DOI: 10.5220/0006588001500156


in Bibtex Style

@conference{biodevices18,
author={N. H. Cherif and N. Mezghani and N. Gaudreault and Y. Ouakrim and I. Mouzoune and P. Boulay},
title={Physiological Data Validation of the Hexoskin Smart Textile},
booktitle={Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2018) - Volume 1: BIODEVICES},
year={2018},
pages={150-156},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006588001500156},
isbn={978-989-758-277-6},
}


in EndNote Style

TY - CONF

JO - Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2018) - Volume 1: BIODEVICES
TI - Physiological Data Validation of the Hexoskin Smart Textile
SN - 978-989-758-277-6
AU - Cherif N.
AU - Mezghani N.
AU - Gaudreault N.
AU - Ouakrim Y.
AU - Mouzoune I.
AU - Boulay P.
PY - 2018
SP - 150
EP - 156
DO - 10.5220/0006588001500156
PB - SciTePress