Image Evaluation in Magnetic Resonance Cholangiopancreatography

K. E. P. Pinho, P. M. Gewehr, A. C. Pinho, A. M. Gusso, C. A. Goedert

2020

Abstract

The objective of this study is to evaluate the image quality with two different contrast agents in MRCP compared to medical evaluation and by using the software Image J®. Natural juices and pulps of different types (açai liquid and powder; and blend) were selected. The selection of patients (31 women and 33 men) was performed at Clinical Hospital, which provides general care in Curitiba city (Brazil). The application of the MRCP protocol followed a sequence tested in healthy volunteers and for the samples described. For image analysis, 2 radiologists participated and were identified as evaluator 1 (E1) and 2 (E2), in order to identify the effect of the contrasts on the images. For the 6 samples tested, only 2 samples remained dark on T2 weighting, which prevents their use as contrast agent. The evaluation of the images was performed separately for each evaluator on different days and places, to identify an appropriate action for the contrasts (A and B). The use of the software (Image J®) allowed a less subjective analysis of the image quality when compared to the evaluation of radiologists and, for the examples presented, a quantitative assessment since the chosen images were submitted to the software analysis.

Download


Paper Citation


in Harvard Style

Pinho K., Gewehr P., Pinho A., Gusso A. and Goedert C. (2020). Image Evaluation in Magnetic Resonance Cholangiopancreatography. In Proceedings of the 13th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2020) - Volume 4: BIOSIGNALS; ISBN 978-989-758-398-8, SciTePress, pages 98-105. DOI: 10.5220/0008987200980105


in Bibtex Style

@conference{biosignals20,
author={K. E. P. Pinho and P. M. Gewehr and A. C. Pinho and A. M. Gusso and C. A. Goedert},
title={Image Evaluation in Magnetic Resonance Cholangiopancreatography},
booktitle={Proceedings of the 13th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2020) - Volume 4: BIOSIGNALS},
year={2020},
pages={98-105},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0008987200980105},
isbn={978-989-758-398-8},
}


in EndNote Style

TY - CONF

JO - Proceedings of the 13th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2020) - Volume 4: BIOSIGNALS
TI - Image Evaluation in Magnetic Resonance Cholangiopancreatography
SN - 978-989-758-398-8
AU - Pinho K.
AU - Gewehr P.
AU - Pinho A.
AU - Gusso A.
AU - Goedert C.
PY - 2020
SP - 98
EP - 105
DO - 10.5220/0008987200980105
PB - SciTePress